Jiangmen Nedar Lighting Co., Ltd.
Guangdong, China
Diamond Member Since 2020
Audited Supplier
Manufacturer/Factory & Trading Company
Sample Available
OEM/ODM Service
Factory Tour
Emergency Battery Backup UPS Power Supply for AC 230V LED Work Light Strip Light
Purchase Qty.: (Pieces) |
100-499 500+ |
---|---|
Reference FOB Unit Price: | US $95.00 US $88.00 |
Usage: | Construction |
---|---|
Output Type: | Single |
Driving Method: | LED Regulator Voltage |
Circuit Structure: | Capacitor Step-down |
Certification: | CE, RoHS |
Power Supply Mode: | Constant Current Source |
Basic Info
Model NO.
EP01
Modulation System
PFM
In-Out
Booster Type
Power Supply Voltage
AC85-265
Pack Sealing Size
SMD
Brand
Nedar
Transport Package
Carton
Specification
285X90X50MM
Trademark
NEDAR
Origin
China
Production Capacity
20000PCS/Month
Product Description
AC230V LED Strip Light Emergercy Power Supply
Model: EP01
Emergency Power Supply is widely used in different kinds of application, using with LED Strip Light is the best solution
for construction site as emergency lighting.
TECHNICAL DATA
Model: | EP01 |
Input Volt.: | AC100-277V ~ 50/60Hz |
Output Volt.: | DC50-180V |
Lamp Power: | 1500W Max. |
Emergency Power: | 50W Max. |
Emergency Time: | 2X60 mins |
Battery Charge: | 24HR(Full charge) |
Input cable: | 1.2M rubber cable 2X1.5mm2 |
Output cable: | 0.5M rubber cable 2X1.5mm2 |
Ta.: | -10~ 50 oC |
Tc.: | Max. 60 oC |
IP Grade | IP65 |
Warranty: | 2 Years |
Product features
1. applicable to all the strip light.
2. when the emergency power supply is started, the voltage is about 175V(emergency voltage);
3. When the emergency power is started, brightness is 30% of the original.
4. the maximum emergency power of emergency power supply is 50W( if the power beyond the range of the emergency power supply will damage the components in case of emergency, so it is not recommended to use it beyond the power range)
5. when emergency power supply works, it is 1 hour within the normal power range(20w~50w). (5m, 25m, 50m strip light are all the same time)
6. The minimum load of emergency power supply is 20W( So the power of the strip light with 1 meter is not enough, and it will be off in about 3 seconds.)
7. charging status: when the charging is less than 90%, the indicator light will be on red light, when charging is more than 90%,the indicator light will be on green light,.
8. Emergency self check: when emergency is started, the green light flashes slowly for 5S + red light flashes slowly for 5S, and if there no load is detected, the output will be turned off.
9. Discharge status: the indicator light flashes green until the indicator light is off and the battery power consumption is finished( It is the used process of emergency power supply )
10. Short press switch: when emergency function is used, short press the switch can display the power quantity by flashing times of red light: flash once corresponds to 0-20% electricity, two times corresponds to 20% - 40%, three times corresponds to 40-60% of electricity, four times corresponding to 60% - 80%, and five times corresponding to 80% - 100%.
11. Long press switch: pressing the switch for more than 3 seconds to turn off the emergency function, and it needs to recharge for reseting the power supply again. After the power is off, the emergency function will be activated again. (2* 1h. when the emergency power working 1 hour, it will turn off itself, and it need charge power to reset, if power off again, the emergency power can still work 1 hour.)